Shock Monitoring on pantograph
Applications
Location: Le Mans, France
Site monitored since: June 2012
overall tasks
A serious failure of pantograph can not only damage contact wires but can also inflict widespread damage on the catenary system network.
Pantographs are subject to regular inspection at rolling stock depots, but some failures are difficult to detect by the visual checks.  In addition, visual check at the depots cannot directly help to quickly detect pantograph failures in operation. A cost-effective and real-time monitoring system during train operation was required by the railway operator.
Our wireless shock sensors (Ref: Beandevice® 2.4GHz AX-3DS) were used to monitor in real-time pantograph defects during train operation.
Thanks to our Smart Shock Detection Mode (SSD), the wireless monitoring system can wakeup on a shock trigger and transmit an alarm notification to field workers.
OPERATION MODE :
DAQ Mode: Smart Shock Detection Mode
Shock thresholds: Shock threshold 5g and 6g, time-hysteresis 5ms
Battery life: 12-14 days with 30-40 shock events per day
EQUIPMENT USED
Caption 2: Wireless IOT sensors coordinator
BeanScape® 2.4GHz Basic  -  Wireless sensor networks supervision software
Caption 1: Wireless IOT sensors supervision software ( Ref: BeanScape® 2.4GHz Basic )
Caption 3: Wireless IOT shock sensors
Caption 4: Wireless IOT shock and impact sensor (Ref: Beandevice® 2.4GHz AX-3DS) is mounted on train pantograph’s damper
Caption 5: Wireless IOT sensors ( BeanGateway® 2.4GHz ) is installed inside suspended ceiling
Caption 6: High shock on the Vertical Z-axis (red color)
Caption 7: Train Pantograph (Overhead line with 25kV AC )
Caption 8:  Several consecutive impacts recorded  on train pantograph.
Caption 9: Catenary deformation at REIMS train station
Caption 10: Damaged carbon contact band
Caption 11 : The Beandevice® 2.4GHz AX-3DS passed successfully all the EMC Stress tests performed by the end user SNCF (French Railway):
Voltage impulsion testing with a rising time of 1us and 1/2/4/6kV of voltage rating
Electrical Field tests at 50Hz and 1/3.6/6/10/15 kV voltage rating  
Magnetic field tests
Current Rating
Frequency
Position
Duration
Results
4,5A (180A/m)
50Hz
Vertical
30s
OK
7,4A (280 A/m)
16,7Hz
Vertical
30s
OK
1,6A (64 A/m)
150Hz
Vertical
30s
OK
1,2A (48 A/m)
200Hz
Vertical
30s
OK
0,8A (32 A/m)
300Hz
Vertical
30s
OK
0,7A (28 A/m)
350Hz
Vertical
30s
OK
0,4A (16 A/m)
600Hz
Vertical
30s
OK
12,5 (500A/m)
uninterrupted
Vertical
1mn
OK
Caption 12: Electrical field testing
Caption 13:  Magnetic field testing